Hook Flash Timing
     
 
The features of your EPABX require the use of a Hook Flash (HF). This is performed by tapping the hook switch of your extension for a period of less than Flash time setted for that extension. Care should be taken not to press the hook switch for more than Flash time when a HF is desired. If the exchange hook switch is pressed for longer than flash time, it will register a "hang up" or "reset". When disconnection is desired care should be taken to press cradle exceeding Flash time or otherwise call will go on Hold and feature tone will be heard (this happens most times when dialed number on CO. is busy and one tries again dialing same number by disconnecting and accessing CO. dials same number so disconnect properly). Some telephone instruments have a built in electronic flash key. It is advisable to use the flash key instead of the hook switch in order to register a "hook flash". This Hook Flash time time is to be setted for each extension individually as per the Instrument Flash Time or Users normal usage of cradle switch. It can done as follows; Lift the handset, on getting dial tone,

Dial   #  1  9  T  T  and hang up.

Where TT is time in milliseconds X 0.1, i.e. it ranges from 400 to 990 milliseconds means user should dial 40 to 99 for TT.

For example, for 650 mSec,

Dial   #  1  9  6  5  and hang up

 