SMDR Recording Start Time after Dialing over.
     
 
The recording start time of the SMDR for outgoing calls starts as per this timings. The service provider most of the time does not provide signaling information regarding maturity of the outgoing call (Battery reversal or 16 KHz pulse) so all outgoing calls are considered matured after this timing is passed once dialing is over.
This timing can be 0 seconds to 9 seconds and can be programmed as follows,

Password + 4 6 * T and hang up

Where T = 0-9 seconds

 For example, if the time required is 5 seconds dial as follows,

Password +  4 6 * 5 and hang up

After this programming the call will get registered in SMDR after 5 seconds are over once dialing is done.

   