Toll Call Control Day Mode (Or Local/STD/ISD Call Restriction)
     
 
Toll calling means making control on the outgoing calls on the trunk lines when the system is operating in day mode. Four different status conditions can be programmed for each extension. To programme this feature, dial as follows,

Password + 5 1 */EXT C

Where,* for All extensions,
Ext for Particular Extension,
C is Code 0 to 3 as follows,
C=0 All allowed,
C=1 Denied table numbers not allowed,
C=2 Restricted table numbers allowed,
C=3 Intercom and lower memory bank numbers are allowed.

For example, to programme extension 30 for all calls, 31 & 32 in denied mode and rest all in intercom only, during day mode, dial as follows,

Password+  5 1 * 3 5 1 3 0 0 5     1 3 1 1 5 1 3 2 1

Here, by * programming one can reduce programming coding. Now extension 30 can dial all numbers but user still have option to use dynamic locking of extension, when not present on extension to avoid misuse and at the same time can dial from other extensions by using walk-in class of service. The extensions 31 & 32 will be only allowed to dial number whose starting digits are not in denied table and the numbers in lower memory bank as well in upper bank, but their digits not same as denied table digits, they can still use dynamic locking. While all other extensions are allowed to use intercom and memory numbers in lower bank. By default all extensions are allowed for all calls.

   
Home    ||     Products     ||     Features     ||     Manuals     ||     Contact Us