The
System have intruder security system feature with
security card attached to it, various optional
security sensors, Panic switch and Hooter can
be connected to the card. The Auto Dialer on break
with allotting one Voice Guidance Chip is programmable.
This optional Security Sensors can be magnetic
contact sensors, Flame detector, Gas detector,
Smoke detector, Glass break detector, PIR etc.
The system can monitor six zones, each zone can
be individually activated as per user’s
requirement. Each zone is programmable for either
normally open or normally close (NO/NC) types
of contacts independently. System can provide
power @ 12V / 500 mAmp (max) for sensors which
requires power. The entry delay and exit delay
are fixed for two minutes. Once all or particular
zones are activated, the system starts monitoring
the activated zones, after two minutes of delay
known as exit delay. After any break is detected,
within any activated zone, the system waits for
two minutes, known as entry delay, for deactivation
that is password protected. Once the entry delay
is over, the auto-dialer is activated and dials
first three memory numbers, one after the other
until the call gets matures. On maturation of
call, the receiver gets voice guidance of the
system. The user can operate the siren as per
requirement, and user can take necessary steps.
The
Siren on break is programmable for activation
on security break or siren can be activated on
receiving security call. Once any zone is activated,
panic switch is pressed, or the security break
is found, the deactivation can be done by executive
user personnel password or system password. On
maturity of the call by auto-dialer, the security
is deactivated, but siren if activated, required
to be deactivated. The security activation can
be done on DISA call with authentic password.
The Panic switch can be of paddle type or push
to ON type, it is to be connected to feature card.
When this switch is pressed the Siren for security
is activated for 10 minutes. This switch is used
for panic situations in Banks, Jewellery Shops,
Factory floor Shops etc. The Security System can
be activated by DISA also.
|
|